TRSS-BNC Signal Surge Protector

Short Description:

TRSS-BNC video signal lightning protection device is mainly used for surge protection of cable television transmission system and CCTV video monitoring system equipment (such as hard disk video recorder, matrix, optical transceiver, camera) of coaxial cable transmission line. It can prevent the above types of system equipment from being struck by lightning or industrial noise caused by induced over-voltage, over-current phenomena and other instantaneous surge voltages to cause permanent damage or instantaneous interruption to the system or equipment.

Product Detail

Product Tags

Product introduction TRSS-BNC video signal lightning protection device is mainly used for surge protection of cable television transmission system and CCTV video monitoring system equipment (such as hard disk video recorder, matrix, optical transceiver, camera) of coaxial cable transmission line. It can prevent the above types of system equipment from being struck by lightning or industrial noise caused by induced over-voltage, over-current phenomena and other instantaneous surge voltages to cause permanent damage or instantaneous interruption to the system or equipment. 1. This series of video signal lightning arresters can be installed in the LPZ0-1 zone or directly connected in series at the front end of the protected equipment (or system). The closer to the protected equipment (or system) during installation, the better 2. The input terminal (IN) of the lightning arrester is connected to the signal line, and the output terminal (OUT) is connected to the protected equipment. It cannot be reversed. 3. The PE wire of the lightning protection device must be connected to the ground of the lightning protection system with strict equipotential connection, otherwise it will affect the working performance. 4. The product does not require special maintenance. Try to lean on the equipment side when installing; when the working system is faulty and suspect that the lightning protector, you can remove the lightning protector and check again. If it is restored to the state before use, it should be replaced. Lightning protection device. 5. Use the shortest wire connection possible for the grounding of the lightning arrester. The grounding of the lightning arrester adopts the terminal grounding method, and the grounding wire must be connected with the lightning protection grounding wire (or the shell of the protected equipment). The shielded wire of the signal can be directly connected to the ground terminal. 6. The lightning protection device does not need long-term maintenance when installed under conditions that do not exceed the requirements. It only requires routine maintenance of the system; if there is a problem with the signal transmission during use, the signal transmission will return to normal after the lightning protection device is replaced. It indicates that the lightning protector is damaged and needs to be repaired or replaced. Product  features 1. Large flow capacity of 10KA (8/20μs). 2. Multi-level lightning protection, fast response, micro insertion loss. 3. The core electronic components are all well-known brands. 4. Tandem installation, simple and convenient installation.


  • Previous:
  • Next:

  • Leave Your Message